Uncertainty evaluation in determination of vitamin B6 in rice flour by microbiological method
-
摘要: 应用微生物法测定米粉样品中维生素B6含量,并从多个方面分析测量的不确定度。试验结果表明:相对合成标准不确定度为0.01393,扩展不确定度为0.1653,测量结果为(5.932±0.1653)μg/hg;影响维生素B6测定结果的最主要不确定度分量为微量移液枪容差。Abstract: In this paper,the content of vitamin B6 in rice flour samples was determined by microbiological method,and the uncertainty of measurement was analyzed from several aspects.The results showed that,the relative synthetic standard uncertainty was 0.01393,the expanded uncertainty was 0.1653,and the result was (5.932 0.1653)μg/100 g.The main uncertainty component affecting the determination results of vitamin B6 is the capacity difference within micro pipette tips.
-
Keywords:
- Microbial method /
- vitamin B6 /
- uncertainty /
- assessment
-
-
[1] 张艳,王甲威,赵相霞.微生物法测定维生素的质量控制[J].中国乳品工业,2014,42(8):54-57. [2] 国家质量监督检验检疫总局.JJF1059-1999测量不确定度评定与表示[S].北京:中国计量出版社,1999. [3] 李慎安.化学试验室测量不确定度[M].北京:化学工业出版社,2006. [4] 国家质量技术监督局计量司组.测量不确定度评定与表示指南[M].北京:中国计量出版社,2000. [5] 郝晓莉,赵瑛博,陈芳芳.分光光度法测定白菜中亚硝酸盐的不确定度评定[J].食品科学,2013,34(6):208-210. [6] 牛华,牛之瑞,冯雷.高效液相色谱法测定辣椒粉中罗丹明B的测量不确定度评估[J].食品科学,2014,35(8):165-168. [7] 王吉祥,张学忠,王亚.气相色谱法和气相色谱-质谱法测定茶叶中联苯菊酯的不确定度评定[J].食品科学,2014,35(12):200-203. [8] 国家质量监督检验检疫总局.JJF1059.12012测量不确定度评定与表示[S].北京:中国计量出版社,2012.
计量
- 文章访问数: 12
- HTML全文浏览量: 0
- PDF下载量: 68